Mkube Auto Titrator for Automated Laboratory Titration
auto titrators
T960 Auto Titrators auto titrators

Auto Titrators (T860 & T960 Models) – Advanced Automatic Potentiometric Titration Systems

Inquiry Now
Category:

Product Description

M-Kube offers advanced Auto Titrators (T860 and T960 Models) designed for accurate and efficient laboratory titration applications. These systems support automatic potentiometric titration, volumetric titration, and Karl Fischer moisture analysis, making them ideal for pharmaceutical, chemical, food, petrochemical, and research laboratories across Australia.

The T860 and T960 Auto Titrators provide reliable automation, precise endpoint detection, and user-friendly operation for high-accuracy analytical testing.

Key Features of Automatic Potentiometric Titrator

  • Advanced automatic potentiometric titrator system 
  • Supports acid-base, redox, precipitation, and complexometric titrations 
  • Compatible with Karl Fischer volumetric titration 
  • Supports coulometric KF titrator applications 
  • High-precision dosing and endpoint detection 
  • Intelligent touchscreen interface with method storage 
  • Automatic result calculation and data management 
  • Multiple electrode compatibility for diverse applications 
  • Stable and repeatable analytical performance 

Typical Technical Specifications: Automatic Potentiometric Titrator

T860 T960 BASIC T960 PRO
Titration module Potentiometric Potentiometric Potentiometric, Dead-stop
mV Measuring range -2000.0 mV +2000.0 mV -2000.0 mV +2000.0 mV -2000.0 mV +2000.0 mV
mV Measuring Resolution: 0.1 mV,

Accuracy: 0.1 mV ± 0.03%

Resolution: 0.1 mV,

Accuracy: 0.1 mV ± 0.03%

Resolution: 0.1 mV,

Accuracy: 0.1 mV ± 0.03%

pH Measuring range -20.000 pH +20.000 pH -20.000 pH +20.000 pH -20.000 pH +20.000 pH
pH Measuring Resolution: 0.001 pH Accuracy: 0.003 pH Resolution: 0.001 pH Accuracy: 0.003 pH Resolution: 0.001 pH Accuracy: 0.003 pH
Temp.Measuring range -5 120℃  -5 120℃  -5 120℃ 
Temp. Accuracy ± 0.1℃ ± 0.1℃ ± 0.1℃
Maximum number of titration modules 4 (2 modules in the standard package) 4 (2 modules in the standard package)
Maximum number of simultaneous filling modules 4 (2 modules in the standard package) 4 (2 modules in the standard package)
Burette optional Standard 5mL;10mL burette, 20ml optional 1mL 5mL 10mL 25mL (10ml burette in the standard package ) 1mL 5mL 10mL 25mL (10ml burette in the standard package )
Burette resolution 1/48000 1/1500000 1/1500000
Burette refill time 16 seconds (100% filling speed) 16 seconds (100% filling speed) 16 seconds (100% filling speed)
User grading management system 4 levels (Customizable operation permissions) 3 level (Customizable operation permissions) 3 level (Customizable operation permissions)
Audit trail
Controlled by PC PC
WiFi module
Stirring Magnetic stirring Magnetic stirring, upper stirring (optional) Magnetic stirring, upper stirring (optional)
Electrode interface type mV/pH measuring electrode interface, reference electrode interface mV/pH measuring electrode interface, reference electrode interface mV/pH measuring electrode interface, reference electrode interface
PT1000 temperature electrode interface, 2* USB. 1 *RS232, power wire port PT1000 temperature electrode interface PT1000 temperature electrode interface, polarized electrode interface 
Autosampler (Optional) Equipped with 1 independent analysis station, optional 16-position 100mL autosampler,

12-position 250mL autosampler, and 18-position 50mL autosampler

Equipped with 1 independent analysis station, optional 16-position 100mL autosampler,

12-position 250mL autosampler, and 18-position 50mL autosampler

 

Applications of Automatic Titration Equipment

  • Pharmaceutical Laboratories
    Accurate titration for drug formulation and quality control. 
  • Chemical & Petrochemical Industry
    Reliable automatic titration equipment for chemical analysis. 
  • Karl Fischer Moisture Analysis
    Karl Fischer volumetric titration and coulometric KF titration for moisture determination. 
  • Food & Beverage Testing
    Titration analysis for acidity, salt, and quality parameters. 
  • Research & Academic Laboratories
    Advanced potentiometric titrator systems for analytical research.

Why Choose M-Kube

  • Reliable automatic titration equipment supplier in Australia 
  • Advanced T860 and T960 Auto Titrator models 
  • Supports potentiometric and Karl Fischer titration methods 
  • Accurate endpoint detection and automated workflows 
  • Technical support and dependable after-sales service 

All M-Kube laboratory instruments are supplied from ISO-certified facilities and tested in accordance with relevant ASTM and international laboratory standards. This ensures reliable analytical performance, accuracy, and long-term operational consistency.

Buy Auto Titrators in Australia – Request a Quote

Looking for automatic titration equipment, potentiometric titrators, or Karl Fischer titration systems?

📞 Call +61-478-594-746
📧 Email info@mkube.com.au 

👉 Contact M-Kube today to discuss your titration requirements and get the best automatic titrator price.

Product FAQ's

Can one titrator perform multiple analytical methods?

Yes, advanced automatic titration equipment can support:

  • Acid-base titration
  • Redox titration
  • Karl Fischer moisture analysis
  • Potentiometric analysis 

Is Karl Fischer volumetric titration suitable for oils and solvents?

Yes, karl fischer volumetric titration is commonly used for:

  • Petroleum products
  • Industrial solvents
  • Edible oils

What causes errors in Karl Fischer coulometric titration?

Common issues in karl fischer coulometric titration include:

  • Moisture contamination from air
  • Dirty titration cells
  • Degraded reagents

What should I verify before comparing automatic titrator price?

When evaluating automatic titrator price, check:

  • Included accessories
  • Electrode compatibility
  • Warranty and service support
  • Software licensing costs

Can a volumetric titrator integrate with laboratory software?

Most modern volumetric titrator systems support:

  • LIMS integration
  • Automated report generation
  • Digital result storage